Air Receiver Tank

We are a leading of vertical air receiver tank and stainless steel chemical receivers tank from Saharanpur, India.

Vertical Air Receiver Tank

Request Callback

₹ 80000 / Piece Get Latest Price

Storage Volume1000 L
Storage Capacity1000 L
Tank Capacity1000 L
Design Pressure10 bar
Material GradeStainless Steel 304
MaterialMS
Usage/ApplicationAIR STORAGE
Frequency50HZ
Rust ProofYES
Country of OriginMade in India

Minimum order quantity: 1 Piece

A vertical  MS and SS air receiver tank is a cylindrical, upright pressure vessel used to store compressed air. Here's a detailed description:Vertical Air Compressor Tank –capacity range -1000L to 5000L
DescriptionA vertical air compressor tank is designed to store compressed air produced by an air compressor. It stands upright (vertically) to save floor space and is commonly used in workshops, factories, garages, and industrial settings. The tank acts as a reservoir to deliver a consistent supply of air and reduce compressor cycling.
Key Features:
Orientation: Vertical (space-saving design)
Material: Usually made of heavy-duty steel or cast iron
Capacity: Ranges from 10 to over 500 liters (or 2.6 to 132 gallons)
Pressure Rating: Typically rated between 100 to 200 PSI (may vary)
Mounting: Fixed base with support legs or brackets
Inlet/Outlet Ports: For air intake from the compressor and output to tools/machines
Drain Valve: Located at the bottom to remove accumulated moisture
Safety Valve: Prevents over-pressurization
Pressure Gauge: Displays internal air pressure
Coating: Internal and/or external corrosion-resistant coating

Advantages:
Saves horizontal floor space
Easier to install in narrow or tight spaces
Provides better air pressure regulation
Suitable for stationary installations

Stainless Steel Chemical Receivers tank

Request Callback

₹ 290000 / Piece Get Latest Price

Storage Capacity5kl
Usage/Applicationindustrial uses
Colorsilver
GradeSS304, SS316
MaterialSTAINLESS STEEL
Rated PressureATMOSPHERIC PRESSURE
Surface FinishingMATT POLISHED
Country of OriginMade in India

Minimum order quantity: 1 Piece

we are GRF DYNAMIC ENGINEERING DEALING WITH STAINLESS STEEL

Here is complete technical information about a 5KL Stainless Steel Chemical Receiver Tank, widely used in industries like pharmaceuticals, chemicals, cosmetics, and food processing for collecting, transferring, and storing liquids.

✅ Basic Overview:

Type: Stainless Steel Chemical Receiver Tank

Capacity: 5000 Liters (5KL)

Orientation: Vertical (commonly) or Horizontal (less common)

Purpose: Temporary or intermediate storage of chemicals or process liquids before further processing or dispatch

Mounting: Leg-supported or skirt-supported

�� Material of Construction (MOC):

Component Material

Shell & Dish Ends SS304 or SS316

Nozzles/Fittings SS304/SS316

Gaskets PTFE / Neoprene

Valves SS Ball / Butterfly type

Cladding (optional) SS304 or Aluminum

SS304: For general use

SS316: For corrosive or pharmaceutical-grade chemicals

�� Design Parameters:

Parameter Value/Range

Working Pressure Atmospheric or up to 2 bar

Design Pressure Up to 3–4 bar (optional)

Working Temperature -20°C to 150°C (typical)

Vacuum Rating Full vacuum if specified

Surface Finish (inside) Mirror (Ra < 0.8 µm) or 2B

Surface Finish (outside) Matte, semi-mirror or polished

�� Typical Dimensions:

> These may vary depending on your height/diameter preference.

Diameter: ~1400–1600 mm

Height (cylindrical body + dish ends): ~2500–3000 mm

Shell Thickness: 4–6 mm

Dish End Thickness: 6–8 mm

Manhole Size: 400–500 mm

�� Standard Accessories & Nozzles:

Inlet nozzle

Outlet nozzle (with flush bottom valve)

Vent/overflow nozzle

Drain nozzle

Manhole with cover

Sight glass (optional)

Level indicator (glass tube or magnetic)

Temperature port (thermowell)

Sampling point

Earthing lug

�� Application Industries:

Bulk Drug & Pharma

Agrochemicals

Fine chemicals

Food and Beverage
Cosmetics & Personal Care

�� Optional Features:

Insulation & Cladding: For thermal retention (hot or cold liquid)

CIP/SIP Systems: Spray balls or ports for in-place cleaning

Agitator: Rare in receiver tanks, but optional if mixing is needed

Load Cell: For weight-based level measurement
Lifting Lugs: For easy movement

�� Testing & Quality:

Hydro Test: Tank is pressure tested for leaks (1.5x design pressure)

Weld Inspection: Visual, Dye Penetration, or X-ray (if needed)

Material Test Certificates (MTCs): Provided with delivery

Surface Roughness Test: For pharma tanks (Ra values)

�� Advanced Design & Engineering Considerations

�� Design Standards (as per industry):

Standard Use Case

ASME Sec VIII Div.1 Pressure-rated receiver tanks

IS 2825 / IS 803 Indian Standard for pressure vessels

GMP/WHO Guidelines Pharmaceutical and food industries

DIN/EN Standards For export to EU or global pharma

�� Construction Details:

Component Specs

Shell Type Cylindrical with torispherical or elliptical dish ends

Welding Type 100% Argon arc (TIG) welding

Support Type 4-legged stand with base plate or skirt with drain tray

Top Lid Hinged or bolted manhole with clamp

Drain Design Sloped bottom with 100% drainable flush bottom valve

⚙ Integration with Process Plants

Receiver tanks often serve as:

Feed or discharge tank to/from a reactor, centrifuge, or filter press.

Buffer tank for batch-wise storage before filling or drying.

Collection tank after distillation, filtration, or condensation.

X

Contact Us

AABAD (Account Manager)
G R F Dynamic Engineering
Opposite Indian Oil Petrol Pump, Shop No.5, Chaudhary Market, C/O Chaudhary Road Car, Dehradun Road, Near Lazman Puram, Opposite Transport Nagar
Saharanpur - 247001, Uttar Pradesh, India

Get Directions
Send Email
Share: